ER PLUS

DESCRIPTION
90° electric actuator, PA6 housing UL 94 V-0 with secured manual override for torques of 10-20-35-60-100Nm and in accordance with CE-ROHS-REACH Directives.

VERSIONS
  • Standard version from 6s to 20s for 90° (without load)
  • Long operating time version from 34s to 110s for 90° (without load)
  • Different possible rotation angles
  • Available with:
  • BBPR - emergency backup
  • POSI - proportional control
  • 3 POSITIONS
  • BLUETOOTH®
  • Modbus-RTU
TECHNICAL DATA
  • Multivoltage actuator:
  • 100V to 240V 50/60Hz (100V to 350V DC)
  • 15V to 30V 50/60Hz (12V to 48V DC)
  • On-off or 3 modulating points control
  • 4 adjustable limit switches 5A
  • Removable adaptation plates:
  • ER 10-35Nm: F03-F04-F05
  • ER 35-100Nm: F05-F07
  • Star drive nut
  • Secured manual override
  • Modular position indicator
  • Integrated anticondensation heater
  • Torque limiter monitored by software
  • Failure feedback relay (normal duty, failure)
  • RS485 connection
  • Mechanical travel stops at 90°
  • Duty rating S4 50% (IEC34)
  • Temperature: -10°C to +55°C
  • Enclosure: IP66
  • Weight: 1Kg - 2.1Kg
  • 1 3P+T DIN43650 connector + 1 ISO M20 (ISO - NPT adapters available as option)



     


           
User manual
ER PLUS user manual

Standards
ER PLUS standards

Catalogue
Valpes actuators catalogue

2D & 3D files
Download actuators 2D and 3D files

Support
Valpes actuators support section

Drive Depth (mm) ISO connection Diameter (mm) threading Depth (mm) Screws number
Star 14 16 F03 36 M5 14,2 4
Star 22 24 F04 42 M5 14,2 4
F05 (ER10/20/35) 50 M6 14,2 4
F05 (ER35/60/100) 50 M6 16,4 4
F07 70 M8 16,4 4


Standard range    
Code Star drive nut
Connection
Torque Voltage supplies Power Operating time (90°)    
without load with load  
ER10.X0A.G00 1) 14/F03-F04-F05 10Nm 100V to 240V 50/60Hz (100V to 350V DC) 15W 9s 11s  
ER10.X0B.G00 1) 14/F03-F04-F05 10Nm 15V to 30V 50/60Hz (12V to 48V DC) 15W 9s 11s  
ER20.X0A.G00 1) 14/F03-F04-F05 20Nm 100V to 240V 50/60Hz (100V to 350V DC) 15W 9s 12s  
ER20.X0B.G00 1) 14/F03-F04-F05 20Nm 15V to 30V 50/60Hz (12V to 48V DC) 15W 9s 12s  
ER35.X0A.G00 1) 14/F03-F04-F05 35Nm 100V to 240V 50/60Hz (100V to 350V DC) 15W 19s 26s  
ER35.X0B.G00 1) 14/F03-F04-F05 35Nm 15V to 30V 50/60Hz (12V to 48V DC) 15W 19s 24s  
ER35.90A.G00 22/F05-F07 35Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 6s 7s  
ER35.90B.G00 22/F05-F07 35Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 6s 7s  
ER60.90A.G00 22/F05-F07 60Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 10s 12s  
ER60.90B.G00 22/F05-F07 60Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 10s 12s  
ER100.90A.G00 22/F05-F07 100Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 20s 23s  
ER100.90B.G00 22/F05-F07 100Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 19s 22s  
long operating time range    
ER35.93A.G00 22/F05-F07 35Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 34s 40s  
ER35.93B.G00 22/F05-F07 35Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 34s 41s  
ER60.93A.G00 22/F05-F07 60Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 67s 79s  
ER60.93B.G00 22/F05-F07 60Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 68s 79s  
ER100.93A.G00 22/F05-F07 100Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 110s 119s  
ER100.93B.G00 22/F05-F07 100Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 110s 119s  
  • 1) Conversion sleeves star 14 to square 9-11 and removable plate F03/F05 or F04 (can be ordered mounted)
  •    
    Options    
    EPR...B 2) 100 / 1000 / 5000 / 10000 Ohms feedback potentiometer  
    EPT.C 3) 0-20mA / 4-20mA / 0-10V transmitter  
    EFC.2 Card with 2 Extra limit switches  
    LC Local control box  
    VIB Version for applications with vibrations  
    HUMPRO Mainboard conformal coating  
    LMO.F03F05 Padlockable manual override (ER10-35)  
    LMO.F05F07 Padlockable manual override (ER35-100)  
    P8 4) AXMART® Bluetooth® and Modbus-RTU, 4-20mA or 0-10V positioning board.  
  • 2) Specify the model
  • 3) Only for a travel time higher or equal to 10s
  • 4) Only feor ER 35 to 100 Nm (ERxx.9xx.G00)
  •    
    Electric connections    
    ECD.1A 1x 3P+T DIN 43650 connector  
    ECM.4 5) 4P M12 power supply connector  
    ECM.8 6) 8P M12 feedback/option connector  
    2PE 2 cable glands  
    NPT.1 7) 1x ISO M20 to 1/2" NPT adapter (ER PLUS • compulsory for CSA)  
    NPT.2 7) 2x ISO M20 to 1/2" NPT adapters (VR / VS • compulsory for CSA)  
    ECD.NPT 7) 1x DIN43650 power supply connector with 1/2" NPT sized entry  
    ECD.1A.NPT 7) 1x DIN43650 feedback connector with 1/2" NPT sized entry  
  • 5) ECM.4: 24 V 50/60 Hz and 24 V DC maximum
  • 6) ECM.8: 24 V 1.5 A maximum
  • 7) NPT connection compulsory for CSA standard
  •    






    For pneumatic actuators and automation, please go to our sister company www.bar-gmbh.com

    Site map

    Products
    Valpes electric actuators
    Options
    Electric connection

    Valpes
    The company
    News
    Sales team
    Contact us
    Location

    Download
    Brochures
    User manuals
    Standards
    Files 2D/3D
    Catalogue and pricelist
    High resolution photos

    Support
    Frequently asked questions
    Video tutorials

    Valpes
    Z.I. Centr'alp • 89 rue des étangs
    38430 Moirans • France
    Tél. +33 (0) 4 76 35 06 06 • Fax +33 (0) 4 76 35 14 34
    valpes-info@wattswater.com • valpes-adv@wattswater.com (for orders)

    Private acces request        |        careers        |        General sales conditions        |        Website using conditions        |        Privacy policy